The flexible detector: ZETALIF DiscoveryTM |
A Sensitive solution for HPLC, fast-LC and CE systems
On-line CE-LIF-MS
On-line LC-LIF-MS
|
|

A LIF solution for Agilent CE |
High Sensitivity: 10 times to 100 times greater
than conventional fluorescence and up to 100,000 times more
sensitive than UV detection. |
Modularity : Adaptable to CE and HPLC systems
including Fast-LC, Capillary LC and nanoLC. |
Versatility: 14 interchangelable different lasers availabls for any application |
Selectivity: Low noise and interference molecules will be detected. Only labeled or native fluorescente
|
|

On-line CE LIF MS |
| Download the Brochure |
|
| ZETALIF Discovery Detector Specifications: |
Capillary :
OD: 365 µm to 460 µm
ID : Refer to Table1 |
| Capillary IDµm |
Estimated*
cell Volume nL |
25 |
0.2 |
50 |
0.4 |
75 |
0.9 |
100 |
1.6 |
150 |
3.5 |
320 |
16.1 |
Table1 : Capillary ID and Volume cell. *Based on 200 µm length of window
|
|
|
Two models are available :
DIS-UV-02 Designed for lasers emitting at wavelengths from 266 to 650 nm.
DIS-VI-02 Designed for lasers emitting at wavelengths from 410 to 780 nm
with optimization of sensitivity for wavelengths from 514 to 650 nm. |
Signal outputs: Analog (processed) 0-1V (DC), 0-100 mV (DC)
Analog (direct) 0-1V (DC) |
Available Lasers :
Laser |
wavelength nm |
Source |
Power |
266 |
Pulsed DPSS |
2mW |
325 |
Helium/Cadmium |
10mW |
355 |
Pulsed DPSS |
2mW |
410 |
Diode |
20mW |
473 |
Diode |
30mW |
488 |
Diode |
25mW |
514 |
Argon ion |
40mW |
532 |
DPSS CW |
15mW |
594 |
Helium/Neon |
2mW |
633 |
Helium/Neon |
10mW |
635 |
Laser Diode CW |
20mW |
650 |
Laser Diode CW |
15mW |
780 |
Laser Diode CW |
40mW |
|
Filter block:
The Filter block depend on the laser and contain the appropriate excitation and emission filter.
Zetalif Discovery detectors are adapted for the use with several lasers. Filter block depend on the laser and contain the appropriate excitation and emission filters.
Contact Picometrics for more information |
Power requirements for the Detector:
100/120 VAC, 50/60 Hz, 0.63 A;
220/240 VAC, 50/60 Hz, 0.315 A |
Data Acquisition Systems:
ZETALIF is compatible with any data acquisition system featuring an analog input (0-1 V).
If no analog input is available, an A/D converter is necessary. |
Distances:
Detector / Cell : 1m (maximum) ; Detector / Laser : 1m (maximum) |
Interface with CE system:
Agilent CE: Internal Detector Adapter kit, UV cassette, and A/D converter (HP.35900E)
are needed. Minimum capillary length total 33 cm/effective 14 cm.
The system works with the ChemStation software.
Beckman P/ACE MDQ: External Detector Adapter kit, MS cassette and an A/D converter (SS420-X)needed. Capillary length: total 53cm/effective 35cm.The system works with the 32 karat software.
Other systems: please contact Picometrics.
|
Interface with HPLC system:
ZETALIF Discovery is compatible with all LC systems but optimal sensitivity is acheived at flow rates < 0.5 mL/min. Lower sensitivity may be observed at higher flow rates. |
Dimensions and weight: 34.0(H) x 17.0(W) x 34.0(D)cm/12,5 kg
|
|